The INGECON SUN STORAGE inverter is a three-phase bidirectional battery converter that can be used in both, grid-connected or stand-alone systems. It complies with the UL1741 and UL9540 standards for North America.

It features string inverter philosophy applied in its design, as the power phases of the power block can be easily replaced. The input and output lines are integrated into the same cabinet, in order to make maintenance work easier.

This battery inverter features a highly advanced battery control technology, ensuring the maximum life of the storage system. The battery temperature could be controlled at all times guaranteeing an enhanced lifespan of the accumulator.

Operating modes:

  • On-Demand Production. It controls the PV plant's output power, limiting it to a desired value.
  • Energy Time Shifting. The inclusion of an ESS makes it possible to inject during the night some of the solar energy produced during the day.
  • Ramp Rate Control. In order to adapt the plant's power output rate to an established setpoint, the battery inverter will minimise the impact of any power variation by absorbing the energy surpluses or by injecting energy into the grid when the PV resource is not enough.
  • Peak-shaving. The energy stored in the batteries could be used to reduce the peaks of power consumption, for those installations with loads coupled to the system.
  • Fast frequency Regulation. In the event of an underfrequency, an additional power injection is needed. The battery inverter will provide this extra power for a certain period of time.
  • Active Power Reserve. Some of the energy stored can be saved in order to feed it to the grid during short periods of time when it is needed.
  • Digital Q Compensation. The battery inverter can control the reactive power output and it can inject reactive power into the grid also during the night.
  • Power Factor Control. Regulation of the power factor at the connection point.
  • Voltage Droop Control. According to an established Droop gain, the system selects the necessary reactive power at the point of connection, depending on the existing voltage difference.
  • Automatic Voltage Regulation. The power plant's voltage can be regulated at the point of connection through a control system applied to the voltage closed loop.
  • Power Oscilations Damping. In those places where the grid is divided in different interconnected zones, the power plant can suffer from low-frequency active power and frequency oscilations. B Series battery inverters in comination with Ingeteam's plant controller allow to implement a control strategy to minimize these oscilations.

Mostra Convegno Expocomfort by maitane.barrena

Details

Mostra Convegno Expocomfort
24-27 March

Website

Mostra Convegno Expocomfort

Direction

Strada Statale Sempione, 28,
20017 Rho MI, Italia

Google Maps
MUBIL by maitane.barrena

Details

MUBIL
25-26 March

Website

MUBIL

Direction

Eskuzaitzeta Industrialdea Oianguren 1,
20160 Zubieta, Gipuzkoa

Google Maps
Asia Pacific Maritime by maitane.barrena

Details

Asia Pacific Maritime
25-27 March

Website

Asia Pacific Maritime

Direction

10 Bayfront Ave,
Singapore 018956,

Google Maps

Do you need more info?

I agree to receive commercial communications from Ingeteam
I have read and I agree to Ingeteam´s privacy terms.
* You have to accept the Ingeteam´s privacy terms.

Ingeteam S.r.l

Via Emilia Ponente 232
48014 Castel Bolognese (RA) Italy
Tel: +39 054... Ver Teléfono
Fax.+39 0546 655391
sales.italia@ingeteam.com