Smart remote terminal units | INGEPAC™ DA AU

INGEPAC™ DA AU devices carry out, in a single device, all the automation, measurement and supervision requirements related to a RMU:

  • Directional phase fault detection
  • Fault isolation automatic operations and load transfer
  • Protection
  • V, I, P and Q measurement of all the positions
  • Local and remote control of switchgear
  • RTU
  • Web server

 

Functions

  • Comprehensive position signaling
  • Complete measurement at the point of installation in the grid: V, I, P, Q, F, cos ϕ, active, reactive energy
  • Voltage measurement using reactive sensors
  • Directional fault passage detection
  • Automatic fault clearance
  • SCADA communication and remote equipment management using software tools or web access
  • Event recording: incidents, faults, oscillography
  • Measurement values log
  • Supply quality values and logs: harmonics, dips, surges, interruptions, etc.
  • IEC 61131-1 logics
  • Communication protocols: DNP3, IEC 103, IEC 61850...

 

Applications

  • Supervision of compact transformer substations (RMU)
  • Centralised control and automation of medium voltage switchgear

The development of communication networks in distribution grids, within the framework of evolving Smart grids, makes it possible to possess a significant amount of information on an entire electrical grid, for the purpose of manual or automatic operation or for making decisions in terms of maintenance and grid development.

INGEPAC DA AU, coupled with voltage sensors, is an affordable solution offering complete measurement and detection of fault bypasses anywhere in the grid. The same device provides communication to the SCADA (RTU) system, remote parameterising using software tools and web access for monitoring and configuration.

Besides supervision functional features, INGEPAC DA AU offers signalling for operating devices and allows the facility to control them remotely and/or automatically.

Benefits:

  • Faster fault identification and location
  • Reduction in customer hour loss
  • Improvement of availability and safety
  • Faster restoration of supply and reduction of outage time

Example of fault detection and isolation in automated transformer substations:

Fault passage isolation

Brochures

INGEPAC™ DA AU flyer


Other Documents

INGEPAC™ SR GR flyer

Voltage sensor for gas-insulated applications

INGEPAC™ SR AR flyer

Voltage sensor for air and pole-mounted switchgear

Clean Currents 2025 by maitane.barrena

Details

Pittsburgh, Pennsylvania
14-17 October

Website

Clean Currents

Direction

1000 Fort Duquesne Blvd,
Pittsburgh, PA 15222,
USA

Google Maps
Colloque National Eolien 2025 by maitane.barrena

Details

Paris, France
15-16 October

Website

Colloque National de France Renouvelables

Direction

Rte de la Pyramide,
75012 Paris,
Francia

Google Maps
Mobility Live 2025 by maitane.barrena

Details

Sydney, Australia
15-16 October

Website

Mobility Live

Direction

14 Darling Dr,
Sydney NSW 2000,
Australia

Google Maps

Do you need more info?

I agree to receive commercial communications from Ingeteam
I have read and I agree to Ingeteam´s privacy terms.
* You have to accept the Ingeteam´s privacy terms.
Smart Grids - Social media

Newsletter: Subscribe

LinkedIn: View page

 

Smart Grids - Contact

E-mail: marketing.pga@ingeteam.com

Phone: (+34) 944 039 600

Address: Ingeteam Power Technology, S. A. - Parque Tecnológico de Bizkaia, Edificio 110 - Zamudio, 48170, Spain