The DUAL INGECON SUN STORAGE Power inverter is a three-phase bidirectional battery converter with two power blocks, that can be used in both, grid-connected or stand-alone systems. It features string inverter philosophy applied in its design, as its power phases can be easily replaced.

This battery inverter features a highly advanced battery control technology, ensuring the maximum life of the storage system. The battery temperature could be controlled at all times guaranteeing an enhanced lifespan of the accumulator.

Operating modes:

  • On-Demand Production. It controls the PV plant's output power, limiting it to a desired value.
  • Energy Time Shifting. The inclusion of an ESS makes it possible to inject during the night some of the solar energy produced during the day.
  • Ramp Rate Control. In order to adapt the plant's power output rate to an established setpoint, the battery inverter will minimise the impact of any power variation by absorbing the energy surpluses or by injecting energy into the grid when the PV resource is not enough.
  • Peak-shaving. The energy stored in the batteries could be used to reduce the peaks of power consumption, for those installations with loads coupled to the system.
  • Fast frequency Regulation. In the event of an underfrequency, an additional power injection is needed. The battery inverter will provide this extra power for a certain period of time.
  • Active Power Reserve. Some of the energy stored can be saved in order to feed it to the grid during short periods of time when it is needed.
  • Digital Q Compensation. The battery inverter can control the reactive power output and it can inject reactive power into the grid also during the night.
  • Power Factor Control. Regulation of the power factor at the connection point.
  • Voltage Droop Control. According to an established Droop gain, the system selects the necessary reactive power at the point of connection, depending on the existing voltage difference.
  • Automatic Voltage Regulation. The power plant's voltage can be regulated at the point of connection through a control system applied to the voltage closed loop.
  • Power Oscilations Damping. In those places where the grid is divided in different interconnected zones, the power plant can suffer from low-frequency active power and frequency oscilations. B Series battery inverters in comination with Ingeteam's plant controller allow to implement a control strategy to minimize these oscilations.

Fichas técnicas

Dual INGECON SUN STORAGE 1500Vdc

Dual INGECON SUN STORAGE 1500Vdc

  • 05/10/2022

    eMove360º

    eMove360° Europe 2022 is the world’s largest trade fair for Mobility 4.0 – electric – connected – autonomous. It presents ...
  • 09/10/2022

    IDA WORLD CONGRESS

    The IDA flagship event returns to Australia a decade from the 2011 IDA World Congress held in Perth. The World Congress will take place during the wee...
  • 10/10/2022

    WEFTEC

    Create Connections. Transform Tomorrow. Tap into the power of your community to transform the future of water. There is no better place than WEFTEC t...

¿Necesitas más información?

Acepto recibir comunicaciones comerciales de Ingeteam
He leído y acepto las condiciones de privacidad de Ingeteam.
* You have to accept the Ingeteam´s privacy terms.

Ingeteam Spa

Los Militares, 5890, Oficina 401,
Las Condes, Santiago- CHILE
Tel: (+56) 22... See phone
chile@ingeteam.com


We use cookies to optimise site functionality and give you the best possible experience.