| INGEDRIVE MV100 | 
        
        
            | General data | 
        
        
            | Inverter type | 
            
            Three-level NPC voltage source inverter with HV-IGBT power semiconductors
             | 
        
        
            | Main supply voltage (1) | 
            
            2 x 1850 VAC (12P DFE) 
            4 x 1850 VAC (24P DFE)
            3300 VAC (AFE)
             | 
            
            2 x 2350 VAC (12P DFE) 
            4 x 2350 VAC (24P DFE)
            4160 VAC (AFE)
             | 
        
        
            | Output power range | 
            
            800 kW - 4.8 MW (air cooled) 
            2.5 MW - 12.7 MW (water cooled)
             | 
        
        
            | Supply voltage tolerance | 
            
            Tipically ± 10%
             | 
        
        
            | Supply frequency | 
            
            50 / 60 Hz (± 5 %)
             | 
        
        
            | Input power factor | 
            
            0.96 for DFE rectifiers 
            1 for AFE rectifiers
             | 
        
        
            | Output voltage (2) | 
            
            0 to 3150 VAC for DFE rectifiers 
            0 to 3300 VAC for AFE rectifiers
             | 
            
            0 to 4160 VAC for DFE rectifiers 
            0 to 4160 VAC for AFE rectifiers
             | 
        
        
            | 
            Output frequency
             | 
            
            0 Hz - 100 Hz (higher on request)
             | 
            
            0 Hz - 70 Hz (higher on request)
             | 
        
        
            | Efficiency  at rated load | 
            
            Tipically > 0.97 for DFE rectifiers 
            Tipically > 0.96 for AFE rectifiers
             | 
        
        
            | Motor types | 
            
            Induction, synchronous or permanent magnet motor
             | 
        
        
            | Converter cooling | 
            
            Air cooled or Water cooled with built-in water to water heat exchanger
             | 
        
        
            | Control properties | 
        
        
            | Control types | 
            
            VC Vector Control / VF Voltage Frequency (3)
             | 
        
        
            | Static speed acc. (closed loop) (4) | 
            
            <0.01% in field weakening / <0.01% at constant flow
             | 
        
        
            | Static torque acc. (closed loop) (4) | 
            
            <1 % in field weakening / <1 % at constant flow
             | 
        
        
            | Static torque acc. (open lloop) (4) | 
            
            <2 % in field weakening / <2 % at constant flow (for synchronous motors) 
            <5 % in field weakening / <3 % at constant flow (for induction motors)
             | 
        
        
            | Torque response time | 
            
            < 10 ms
             | 
        
        
            | Shaft torque ripple (4) | 
            
            ± 1 % 
             | 
        
        
            | Drive protection functions | 
            
            Overcurrent, overvoltage and undervoltage monitoring; earth fault; short circuit detection and protection; semiconductor failure monitoring; cooling supervision; phase loss and others
             | 
        
        
            | Motor protection functions | 
            
            Overload (5), Overspeed
             | 
        
        
            | Environmental Conditions | 
        
        
            | Ambient temp. for storage | 
            
            - 15 ºC to  + 75 ºC (for empty cooling system in water cooled version)
             | 
        
        
            | Ambient temp. for transport | 
            
            - 15 ºC to  + 75 ºC (for empty cooling system in water cooled version)
             | 
        
        
            | Operation altitude | 
            
            < 1000 m  above sea level (100 % load capacity) 
            > 1000 m  above sea level (with derating)
             | 
        
        
            | Relative air humidity | 
            
            5 % - 95 % (condensation not permitted)
             | 
        
        
            | Paint colour | 
            
            RAL 7035 (others on request)
             | 
        
        
            | Compliance with standards | 
            
            IEC 61800-4, IEC 60146-1-1, marine standars
             | 
        
        
            | Air cooled converter | 
        
        
            | Noise | 
            
            < 85 dB (A) at a distance of 1m from the cubicle
             | 
        
        
            | Ambient temp. for operation  | 
            
            + 0 ºC to + 40 ºC (higher with derating)
             | 
        
        
            | Degree of protection | 
            
            IP21 (others on request)
             | 
        
        
            | Water cooled converter | 
        
        
            | Noise | 
            
            <75 db (A) at a distance of 1m from the cubicle
             | 
        
        
            | Ambient temp. for operation  | 
            
            + 0 ºC to + 45 ºC (higher with derating)
             | 
        
        
            | Degree of protection | 
            
            IP44 (others on request)
             | 
        
        
            | Primary circuit coolants allowed | 
            
            Seawater or freshwater
             | 
        
        
            | Primary coolant temp. allowed | 
            
            + 0 ºC to + 38 ºC (higher with derating) 
             | 
        
        
            | Primary circuit pressure drop | 
            
            < 1.5 bar 
             | 
        
        
            | Max. primary service pressure | 
            
            6 bar 
             | 
        
        
            | Max. primary ΔT | 
            
            6º C 
             | 
        
        
            | Secondary circuit coolant | 
            
            Controlled pre-mixed liquid (fresh water < 10 µS/cm + anti-freezing) 
             | 
        
        
            | Secondary circuit features | 
            
            Redundant pump
             | 
        
        
            | Main Options | 
        
        
            | 
            Dynamic braking chopper, different communication modules, dv/dt filter, sinusoidal filter, input / output isolation switch, motor grounding switch, marine customization and others
             |