| INGESYS IC2 |
| Power Source |
| Main Power Supply* |
24Vdc (+25% / -30%) Class S2 (EN 50155:2017)
36-48Vdc (+25% / -30%) Class S2 (EN 50155:2017)
72-110Vdc (+25% / -30%) Class S2 (EN 50155:2017)
|
| Maximum Consumption |
24V @ 300mA / 110V @ 80mA |
| Dissipated Power |
8W (max.) |
| Processor Module |
| Main Processor |
32bit, 400MHz |
32bit, Dual Core 800Mhz |
| Memory |
Up to 128MB
Program: 1MB
Data: up to 1MB
Non volatil data: 62KB |
512MB
Program: 4MB
Data: up to 4MB
Non volatil data: 128KB |
|
Registry: 32MB up to 8GB
|
| Program |
IEC61131-3, specific functions communication and regulation library |
| Monitoring and Maintenance |
Embedded Web Server
Local LCD Text Display (optional)
USB Port for upload / download: firmware, application, data register…
|
| LAN |
2 Ethernet 10/100Base TX M12 (internal switch)
|
2 Ethernet 10/100Base TX M12 |
| Additional 1 Ethernet 10/100Base TX M12 (optional) |
| Protocols: Modbus TCP/IP, TRDP, Ethernet/IP, CIP, PROFINET I/O, SFTP |
| Field buses |
Up to 4 selectable Ports per CPU: CANOpen (Master/Slave), Profibus DP (Slave), RS232/RS485, MVB ESD+, MVB EMD |
| Wireless Interface |
3G, 4G and WiFi standard 802.11 a/b/g/n
|
| Input/Output Modules** |
| Digital Intputs |
16 DI (24Vdc @ 3mA) (PNP or NPN)
8 DI (24-110Vdc) (PNP or NPN) |
| Digital Outputs |
16 DO (HSD 24Vdc @ 500mA) (PNP o NPN)
8 DO (24VDC @ 2A)
8 DO (24-110Vdc @ 1.5A) |
| Relay Outputs |
3 Electromechanical relay outputs with switched contacts (150V @ 5A) |
| Mixed Digital I/Os |
8 DI (24Vdc @ 5mA) + 8 DO (HSD 24Vdc @ 500mA)
12 DI (24Vdc @ 5mA) + 4 DO (HSD 24Vdc @ 500mA)
4 DI (24Vdc @ 5mA) + 12 DO (HSD 24Vdc @ 500mA) |
| Analog Inputs |
8 AI (±10V or ± 20mA)
8 AI (PT100, NTC or Thermocouple)
8 fast synchronous AI, up to 100Ks/s, for (±10V or ± 20mA) or IEPE accelerometers
1 AI + 4 IEPE inputs + 1 High Speed Counter
10 Temperature inputs |
| Analog Outputs |
8 AO (±10V or ± 20mA) |
| Motor Control |
4 DI (24Vdc@ 5mA) + 1 Encoder input + 1 PWM output ( 5A) H-bridge topology
|
| Audio |
2 Audio outputs 2W |
| Standards |
| Immunity and Emission |
EN 50121-3-2:2016 |
| Temperature Range |
EN 50155:2017 [OT4 (-40ºC +70ºC)] |
| Vibrations |
EN 50155:2017 [Body Mounted, Class B] / IEC 61373:2010 |
| Fire Protection |
EN 45545-2 |
| Mechanical Features |
| Assembly |
Panel Mount |
| Material |
Aluminium |
Dimensions
(W x H x D) |
(149mm to 524mm)*** x 135mm x 34.6mm |