The DUAL INGECON SUN STORAGE Power inverter is a three-phase bidirectional battery converter with two power blocks, that can be used in both, grid-connected or stand-alone systems. It features string inverter philosophy applied in its design, as its power phases can be easily replaced.

This battery inverter features a highly advanced battery control technology, ensuring the maximum life of the storage system. The battery temperature could be controlled at all times guaranteeing an enhanced lifespan of the accumulator.

Operating modes:

  • On-Demand Production. It controls the PV plant's output power, limiting it to a desired value.
  • Energy Time Shifting. The inclusion of an ESS makes it possible to inject during the night some of the solar energy produced during the day.
  • Ramp Rate Control. In order to adapt the plant's power output rate to an established setpoint, the battery inverter will minimise the impact of any power variation by absorbing the energy surpluses or by injecting energy into the grid when the PV resource is not enough.
  • Peak-shaving. The energy stored in the batteries could be used to reduce the peaks of power consumption, for those installations with loads coupled to the system.
  • Fast frequency Regulation. In the event of an underfrequency, an additional power injection is needed. The battery inverter will provide this extra power for a certain period of time.
  • Active Power Reserve. Some of the energy stored can be saved in order to feed it to the grid during short periods of time when it is needed.
  • Digital Q Compensation. The battery inverter can control the reactive power output and it can inject reactive power into the grid also during the night.
  • Power Factor Control. Regulation of the power factor at the connection point.
  • Voltage Droop Control. According to an established Droop gain, the system selects the necessary reactive power at the point of connection, depending on the existing voltage difference.
  • Automatic Voltage Regulation. The power plant's voltage can be regulated at the point of connection through a control system applied to the voltage closed loop.
  • Power Oscilations Damping. In those places where the grid is divided in different interconnected zones, the power plant can suffer from low-frequency active power and frequency oscilations. B Series battery inverters in comination with Ingeteam's plant controller allow to implement a control strategy to minimize these oscilations.

Importante contrato de O&M eólico en México que consolida el posicionamiento de Ingeteam en el país by Jara

Se trata de casi 500 MW para la prestación de servicios de Operación y Mantenimiento en 5 parques eólicos ubicados en Oaxaca y San Luis Potosí.

Nueva Familia INGEDRIVE LV800 by Jon.Laurrieta
Ferias y eventos 2021 un año lleno de oportunidades by Jon.Laurrieta
Ingeteam se adjudica el mantenimiento de una de las plantas mexicanas más potentes del país by Jara

Ø  Se trata de un nuevo contrato para dar mantenimiento a la planta Magdalena II de Enel Green Power Mexico que supone dar soporte a una instalación de 550.000 paneles bifaciales y 220 MW de potencia.

Ø  Evita la emisión anual de aproximadamente 350.000 toneladas de CO2 a la atmósfera

Ø  Para esta planta Ingeteam también ha suministrado un sistema de protección, control y medida para la subestación elevadora.

Ingeteam suministra la primera estación de recarga para vehículos eléctricos con almacenamiento de energía de España by Nair
Ingeteam recibe un nuevo pedido para automatizar la red de distribución secundaria en Tailandia by Sergio

Datasheets

Dual INGECON SUN STORAGE 1500Vdc

Dual INGECON SUN STORAGE 1500Vdc

Do you need more info?

I agree to receive commercial communications from Ingeteam
I have read and I agree to Ingeteam´s privacy terms.

Ingeteam S.r.l

Via Emilia Ponente 232
48014 Castel Bolognese (RA) Italy
Tel: +39 054... Ver Teléfono
Fax.+39 0546 655391
sales.italia@ingeteam.com